Closed tender

Water Mist Suppression System Replacement

Details

Value
£2,962,195
Topic
Firefighting equipment installation work
Published
26 September 2025
Submission
24 November 2025

Tender description

The Water Mist Suppression and Sprinkler Systems requirement is for the procurement of a principal contractor to remove, replace and commission the Water Mist Suppression and Sprinkler Systems currently installed in 34 locations situated within 22 different London Underground stations. TfL's has identified that the fire suppression and sprinkler systems currently installed in the sites (Cleaner's Stores, Bin Stores, Stores and Retail Tenancies) are either life-expired, non-compliant or not fit for purpose under Article 5 of the Fire Precautions Sub-surface Railway Regulations 2009. It has also been identified that these systems do not have / meet the current applicable standards such as BS EN14279 and BS8489. The water mist systems have been installed on the TfL infrastructure in the early 1990's following the publication of the Fire Precautions Sub-surface Railway Regulations 1989 (updated 2009). The systems were installed where conventional sprinkler systems were not considered viable due to practical or logistical constraints and designed, installed and maintained in compliance with the American Standard NFPA750. Due to the increasing number, sizes, type of storage and trading activities within the network, further review of risks and tests for these suppression protection systems were undertaken and evaluated. This confirmed a requirement to replace these systems and design modern, compliant equivalent water mist system to replace the ageing noncompliant systems currently installed in the TfL LU estate. The modern systems will be tested by TfL to BS EN 14972-1 Annex A with a deluge time of not less than 60 minutes from the appropriate number of cylinders located locally, to provide reliable fire suppression to specific rooms identified. These new installations will be designed for but not limited to Cleaner's Stores, Bin Stores, Stores and Tenancies. In some cases, wet sprinklers systems extensions will replace the ageing Water Mist systems where they are available and economically viable.

Timeline

  1. Completed: Tender published26 September 2025
    Current notice
  2. Completed: Submission date24 November 2025

About the buyer

Transport for London operates the capital's transport network for the Mayor of London, and buys as a local government organisation on behalf of TfL, the Greater London Authority and the Old Oak and Park Royal Development Corporation.

Rail-related work can be sourced through RISQS, the rail industry supplier qualification scheme, without a published tender notice.

Over the past 5 years, most of Transport for London's contract awards have been in transport services, business services and repair and maintenance.

AI insights

  • Is there a preferred supplier?
  • What are the buyers pain points?
  • What has the buyer previously procured?
  • What are the key requirements?
Sign-up to enrich

Decision makers

Connect with the people behind this procurement.

Contact nameJob titlePhone numberWork email
Head of Procurement+44 •••• ••••••
Commercial Director+44 •••• ••••••
Procurement Manager+44 •••• ••••••
Category Lead+44 •••• ••••••
Senior Buyer+44 •••• ••••••
Contracts Manager+44 •••• ••••••

8 similar open tenders

See more open tenders related to Firefighting equipment installation work.

Explore all open tenders

Related topics

Topics related to Water Mist Suppression System Replacement, ranked by notice volume.

View all topics

Finding public sector work shouldn't be hard

Make your next tender search effortless with Stotles. Set up alerts, find decision maker contacts and never miss a good-fit opportunity again.