Awarded contract

Published

Purchase of Stimulated Raman Laser & Multi-Channel Lock-In Amplifier

7 suppliers have saved this notice.

Looks like a fit? Save this tender and qualify it in Stotles

Value

168,000 EUR

Current supplier

CAMBRIDGE RAMAN IMAGING LTD

Description

Purchase of Stimulated Raman Laser & Multi-Channel Lock-In Amplifier for research purposes Lot 1: The University requires to purchase from supplier-Cambridge Raman Imaging SrL the following: STRALE – laser system for broadband stimulated Raman scattering (SRS) in a full CH-stretching region detected in a single shot, with no need for sequential tuning of the emitted wavelengths, while preserving high spectral resolution. Key features of the system: Integrated pump beam modulator: modulation frequencies from 1 to 10 MHz Central wavelengths: pump 792 nm ± 1 nm, Stokes 1030 nm FWHM spectral width: pump ≤ 1 nm, Stokes ≥ 30 nm Output power: pump > 70 mW @ 1–10 MHz modulation; Stokes > 180 mW @ 20 MHz rep. rate Pulse energy: pump > 7 nJ, Stokes > 9 nJ Pulse width: pump < 2 ps ; Stokes < 0.2 ps Wavenumber coverage [cm⁻¹]: 2800–3100 (full CH‑stretching region) Wavenumber resolution [cm⁻¹]: < 16 Synchronized dual output Air‑cooled, compact footprint: 610 × 390 × 395 mm Embedded control and power electronics CHAMP - multichannel lock-in amplifier spectrometer is an optical spectrometer based on CRI proprietary multi-channel lock-in technology, ensuring extremely low electronic noise levels, high spectral resolution and short integration time. It has been designed to detect tiny variations, as small as one part over 10 millions, in few microseconds. A unique solution on the market for pixel-wise broad vibrational spectra reconstruction at megahertz modulation frequencies. Key features of the spectrometer: 38 lock‑in amplifiers with independent AC (demodulated) and DC (average power) outputs Triggerable integration‑time averaging up to 30 ms Demodulation frequency range: 1–10 MHz Demodulation phase: 0–360° in 32 steps per channel Shot‑noise‑limited acquisition down to ~25 µW per channel Noise‑equivalent power (NEP): < 20 pW/√Hz Fixed filter time constant: 0.5 µs Vertical resolution: 16 bit Spectral resolution: < 9 cm⁻¹ * Real‑time demodulated‑signal normalization Pixel‑ and line‑triggered synchronized acquisition USB 3.0 PC connection for fast data transfer Two additional analog inputs and outputs for PMT acquisition Following market research carried out by the academic research team, there are no other suppliers available in the market to supply this type of equipment in the form factor required. The principal purpose of the contract is to acquire goods in connection with research undertaken by the University.

Never miss a tender again

Get alerts, AI summaries and tools to qualify faster

Explore similar pre-tenders, open or awarded contracts

Browse open tenders, recent contract awards and upcoming contract expiries that match similar CPV codes.

University of Edinburgh

128,734.38 GBP

Published a day ago

Heriot Watt University

168,000 EUR

Published a day ago

University of Edinburgh

128,734.38 GBP

Published a day ago

Bradford Teaching Hospitals NHS Foundation Trust

23,171.15 GBP

Published 2 days ago

University of Edinburgh

91,590 GBP

Published 3 days ago

Northumbria Healthcare Facilities Management Ltd

32,764.08 GBP

Published 3 days ago

University of Edinburgh

91,590 GBP

Published 3 days ago

University of Edinburgh

120,000 GBP

Published 10 days ago

University of Edinburgh

63,711 GBP

Published 13 days ago

Sign up to the Stotles Tender Tracker for free

Find even more contracts with advanced search capability and AI powered relevance scoring.