Awarded contract

Published

Atmospheric gas analyser

4 suppliers have saved this notice.

Looks like a fit? Save this tender and qualify it in Stotles

Value

82,840 EUR

Current supplier

GeoGas Analytica

Description

SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable). Lot 1: SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).

Never miss a tender again

Get alerts, AI summaries and tools to qualify faster

Explore similar pre-tenders, open or awarded contracts

Browse open tenders, recent contract awards and upcoming contract expiries that match similar CPV codes.

University of Edinburgh

82,840 EUR

Published 10 days ago

Yorkshire Water Services Ltd

81,000,000

Published 8 months ago

Southampton City Council

24,450 GBP

Published 9 months ago

NHS Wales - Shared Services Partnership

250,000

Published a year ago

NHS Wales - Shared Services Partnership

250,000

Published a year ago

Stroud District Council

25,800 GBP

Published 2 years ago

Kirklees Council

70,950 GBP

Published 2 years ago

Department for Environment, Food & Rural Affairs

480,000 GBP

Published 2 years ago

Sign up to the Stotles Tender Tracker for free

Find even more contracts with advanced search capability and AI powered relevance scoring.